GROW K226+G16 Fingerprint Control Board
Page view:
产品名称

GROW K226+G16 Fingerprint Control Board

Power Supply
DC10-30V
Stand-by Mode Current
6mA(DC12V)
Fingerprint Capacity
100
Output
Relay(Max. current: 10A)
Quantity
-
+
没有此类产品
DETAIL
Product parameters
Technical Parameters:
·Power supply: DC10-30V
·Stand by current: 6mA(DC12V)
·Output: Relay(Max. current: 10A)
·Fingerprint capacity:
Administrator fingerprint:40 pieces
User fingerprint:60 pieces(30pieces*2 database)
·Password capacity:
Administrator Password: 5 groups
User Password: 5 groups (Length: 3-9 bits)
One-time Password: 5 groups
·Password Using: Password【OK】
·Management: SET Button or Fingerprint or Password
 
 
Operation Instruction:
(The first time to use, pls long press the SET Button to back to factory first) 
1.SET Button
1.1  Register Administrator Fingerprint: 
Press SET button shortly,blue indicator light flash fast means system in register state, press several times for each finger in the collection area,fingerprint register successful when hearing music. Fingerprint can be registered continuously when system in register state; if no need adding fingerprint more, waiting a few seconds to exit. After the 40 pieces of administrator fingerprint is stored full, then press the SET button will register user fingerprints. 
1.2  Back to Factory Mode: Long press the SET button until hear “Di” long beep and music,means initialization operation successful.
 
 
2.Keyboard Setting
For all operation settings,need to press the administrator fingerprint or administrator password first. After relay pass, then can edit. 
Password Using: E.g.:Add Administrator Fingerprint: Password【OK】1【OK】
 
2.1. Add Administrator Fingerprint: Pass the administrator's fingerprint/password,enter in edit mode:Press: 1【OK】,blue indicator light flash fast, press several times for each finger in the collection area, fingerprint register successful when hearing music,fingerprint can be registered continuously,fingerprint inventory is full when hearing “DiDiDi” and red light flashing
Note: The administrator fingerprint cannot be repeated with the user fingerprint. If repeated, there will be error report and red light flashing.
2.2. Clear the System and Back to Factory Mode: Pass the administrator's fingerprint/password,enter in edit mode: Press: 1【C】(Long press C)
2.3. Set Administrator Password: Pass the administrator's fingerprint,enter in edit mode: Press: 2【OK】New Password【OK】(Can set 5 groups)
2.4. Delete Administrator Password: Pass the administrator's fingerprint/password,enter in edit mode: Press: 2【C】(Long press C)
2.5. Set User Fingerprint: Pass the administrator's fingerprint/password,enter in edit mode:Press: 3【OK】Database position (1 or 2)【OK】, E.g.: 3【OK】1【OK】,blue indicator light flash fast, press finger for each fingerprint, fingerprint register successful when hearing music,fingerprint can be registered 30 pieces continuously(each database capacity is 30 pieces),fingerprint inventory is full when hearing “DiDiDi” and red light flashing
Note: The user fingerprint cannot be repeated with the administrator fingerprint. If repeated, there will be error report and red light flashing.
2.6. Delete User Fingerprint: Pass the administrator's fingerprint/password,enter in edit mode:Press: 3【C】Database position (1 or 2)【C】(Long press the second C)
2.7. Set User Password: Pass the administrator's fingerprint/password,enter in edit mode:
Press: 4【OK】New Password【OK】(Can set 5 groups)
2.8. Delete User Password: Pass the administrator's fingerprint/password,enter in edit mode:Press: 4【C】(Long press C)
2.9. Relay Mode Setting:Pass the administrator's fingerprint/password,enter in edit mode: Press: 5【OK】Relay Mode(1-4)【OK】
Mode 1: The relay time is adjusted by variable resistance:0.5-20 s;
Mode 2: The relay opens when the finger is pressed, and closes after the finger is released.
Mode 3: Press finger-Relay open, then press finger again-Relay closed. Do not save relay status when power is cut off
Mode 4: Press finger-Relay open, then press finger again-Relay closed. Save relay status when power is cut off.
3.0. Set One-time Password: Pass the administrator's fingerprint/password,enter in edit mode:Press: 6【OK】New Password【OK】
Can be set 5 groups, will be invalid after being used once
3.1. Delete One-time Password: Pass the administrator's fingerprint/password,enter in edit mode:Press: 6【C】(Long press C) ,delete all one time password
 
 
 
Corresponding parameter set not found, please add it in property template of background
暂未实现,敬请期待
暂未实现,敬请期待
Previous article